| 1 | Manufacturer Profile 01 | 100–277 V AC or 120–277 V AC; confirm frequency compatibility for the destination market. | IEC 60598-1; IEC 60598-2-3; applicable regional safety requirements. | IP66 minimum target for sealed outdoor street-light housings. | Independent test reports, photometric files, surge-protection details, and production traceability. | Multi-voltage municipal and roadway projects. | Critical |
| 2 | Manufacturer Profile 02 | 220–240 V AC; verify 50 Hz operation and tolerance range before purchase. | IEC 60598-1; IEC 60598-2-3; EN 55015 where required. | IP65–IP66, depending on road environment and housing design. | Electrical-safety documentation, EMC test evidence, thermal-management data, and warranty terms. | European, Middle Eastern, African, and Asian grid applications. | High |
| 3 | Manufacturer Profile 03 | 90–305 V AC wide-input design; verify power-factor performance across the full range. | IEC 60598 series; IEC 61000-3-2; IEC 61000-3-3, where applicable. | IP66 with corrosion-resistant aluminum housing and protected cable entry. | Input-voltage test results, power-factor data, total-harmonic-distortion data, and wiring diagrams. | Projects exposed to unstable or varying utility voltage. | Critical |
| 4 | Manufacturer Profile 04 | 120–277 V AC; confirm compatibility with local surge and grounding requirements. | IEC 60598-1; IEC 60598-2-3; IEC 61000-4 series for immunity testing. | IP66 and IK08 or higher where vandalism or roadside impact is a concern. | Ingress-protection report, impact-resistance evidence, grounding method, and surge-protection rating. | Urban streets, public facilities, and high-traffic areas. | Critical |
| 5 | Manufacturer Profile 05 | 220–277 V AC; verify driver efficiency and operating temperature limits. | IEC 60598-1; IEC 60598-2-3; IEC 61347-1 and IEC 61347-2-13 for LED controlgear where applicable. | IP66; use corrosion testing suitable for coastal or industrial locations. | LED-driver datasheet, thermal test report, salt-spray evidence where relevant, and maintenance instructions. | Coastal highways, ports, and industrial districts. | High |
| 6 | Manufacturer Profile 06 | 100–240 V AC; confirm regional voltage, frequency, and dimming-interface compatibility. | IEC 60598 series; IEC 62384 for electronically controlled LED drivers where applicable. | IP65 minimum; IP66 preferred for heavy rain, dust, and wash-down exposure. | Dimming compatibility statement, control-interface documentation, photometric distribution files, and commissioning support. | Smart-city and adaptive-lighting deployments. | Critical |
| 7 | Manufacturer Profile 07 | 120–277 V AC; verify operation with photocells, timers, or networked control nodes. | IEC 60598-1; IEC 60598-2-3; relevant control-system and EMC requirements. | IP66 with replaceable or serviceable surge-protection components. | Control compatibility list, surge-protection replacement procedure, spare-parts plan, and service training. | Long-term municipal maintenance programs. | High |
| 8 | Manufacturer Profile 08 | 85–305 V AC; verify low-voltage starting behavior and driver protection functions. | IEC 60598-1; IEC 60598-2-3; IEC 61547 for lighting-equipment immunity where applicable. | IP66 and IK08 target for exposed road infrastructure. | Low-temperature test results, surge-current data, driver protection functions, and batch inspection records. | Cold climates and regions with utility fluctuations. | High |
| 9 | Manufacturer Profile 09 | 220–240 V AC; verify compatibility with local protective devices and earthing systems. | IEC 60598-1; IEC 60598-2-3; IEC 61000-3-2 for harmonic-current limits where applicable. | IP66; confirm gasket, lens, and enclosure materials for the local climate. | Declaration of conformity, component list, photometric measurement report, and quality-control plan. | Standardized tender projects with strict documentation requirements. | High |
| 10 | Manufacturer Profile 10 | 100–277 V AC; verify regional certification, labeling, and import documentation. | IEC 60598 series; ISO 9001 quality-management evidence; local market approvals where required. | IP65–IP66; confirm IK rating and corrosion protection according to the installation site. | ISO 9001 certificate scope, factory-audit access, sample approval process, warranty, and after-sales response time. | International distributors and multi-country procurement programs. | Critical |