| Micro | 8–20 kW | 9–22 kW | Small workshops, retail stores, rural facilities and backup power for homes | Approx. 2.8–6.5 L/h at full load | Three-phase, 400/230 V, 50 Hz; PF 0.8 | Compact enclosure, low noise, simple controller and reliable cold starting |
| Small | 25–50 kW | 28–55 kW | Restaurants, offices, farms, telecom shelters and light industrial loads | Approx. 7–15 L/h at full load | Three-phase, 400/230 V, 50 Hz; PF 0.8 | Automatic transfer compatibility, battery charger and overload protection |
| Medium-Low | 60–100 kW | 66–110 kW | Commercial buildings, schools, clinics and medium-sized construction sites | Approx. 17–29 L/h at full load | Brushless alternator with automatic voltage regulation | Motor-starting capability, phase monitoring and adjustable protection settings |
| Medium | 120–200 kW | 132–220 kW | Factories, hotels, data rooms, water pumps and larger commercial facilities | Approx. 34–58 L/h at full load | Low-voltage alternator; PF 0.8 unless the load requires otherwise | Adequate radiator capacity, low-voltage distribution and service access |
| Medium-High | 250–400 kW | 275–440 kW | Manufacturing plants, hospitals, logistics centers and large building services | Approx. 70–115 L/h at full load | High-efficiency brushless alternator with AVR | Load-step performance, harmonic compatibility and emergency ventilation design |
| Large | 450–650 kW | 495–715 kW | Heavy industry, major commercial buildings, mining support and utility projects | Approx. 125–185 L/h at full load | Alternator selected for continuous thermal duty | Fuel autonomy, remote monitoring, acoustic treatment and lifting provisions |
| High | 700–900 kW | 770–990 kW | Large factories, infrastructure projects, airports and mission-critical facilities | Approx. 195–260 L/h at full load | Heavy-duty alternator with suitable short-circuit performance | Parallel operation, synchronizing controls and high-capacity fuel storage |
| Very High | 1,000–1,500 kW | 1,100–1,650 kW | Data centers, large plants, transport infrastructure and standby power stations | Approx. 280–430 L/h at full load | Medium-voltage option may be required for site distribution | Redundancy, rapid load acceptance, fire protection and detailed commissioning |
| Very Large | 1,600–2,000 kW | 1,760–2,200 kW | Large data facilities, industrial campuses and critical infrastructure | Approx. 450–575 L/h at full load | Alternator and switchgear engineered for the site voltage | Load-bank testing, synchronization studies and planned maintenance support |
| Multi-Set System | 2,000 kW and above | Project-specific | Utility support, major infrastructure, industrial campuses and high-availability facilities | Calculated from the selected engine and operating load | Multiple alternators with synchronized switchgear | N+1 redundancy, automatic load sharing, black-start strategy and system integration |