| 1 | Active 1-to-2 Analog Splitter | One 4–20 mA input to two independent 4–20 mA outputs | Usually input-to-output and output-to-output isolation | External DC supply, commonly 18–32 VDC | Approximately ±0.1% of span | Typically 10–30 ms | Sending one transmitter signal to a PLC and a control system | Verify output load capacity and the number of isolated channels |
| 2 | Active 1-to-3 Analog Splitter | One 4–20 mA input to three separately powered outputs | Normally galvanically isolated on each output | External DC supply, commonly 18–32 VDC | Approximately ±0.1% to ±0.2% of span | Typically 10–40 ms | Process control, alarm monitoring, recording, and indication | Check total power consumption, terminal layout, and enclosure width |
| 3 | Passive Loop-Powered Splitter | One 4–20 mA loop distributed to two passive outputs | Often non-isolated; isolated versions require careful loop-power design | Powered by the current loop; no separate supply in basic designs | Approximately ±0.2% to ±0.5% of span | Typically 20–100 ms | Low-power field instruments and retrofit installations | Calculate loop voltage drop and confirm the available compliance voltage |
| 4 | Galvanically Isolated Splitter | One input with electrically separated output circuits | Input, output 1, and output 2 are electrically isolated | External DC supply, commonly 18–32 VDC | Approximately ±0.1% to ±0.2% of span | Typically 10–30 ms | Breaking ground loops and protecting control equipment | Review isolation voltage, common-mode limits, and EMC specifications |
| 5 | Non-Isolated Signal Splitter | One 4–20 mA input buffered into two outputs sharing a common reference | No galvanic isolation between circuits | External DC supply, commonly 12–32 VDC | Approximately ±0.1% to ±0.3% of span | Typically below 20 ms | Cabinet systems with a common grounding and power arrangement | Use only where ground-potential differences are not a concern |
| 6 | HART-Transparent Splitter | 4–20 mA signal duplication while allowing HART communication to pass | Usually isolated; design-dependent | External DC supply is typical | Approximately ±0.1% to ±0.2% of span | Typically 10–50 ms for the analog signal | Smart transmitters requiring simultaneous control and configuration access | Confirm HART pass-through, input impedance, and communication wiring method |
| 7 | DIN-Rail Analog Splitter | Compact 4–20 mA distribution module for control cabinets | Isolated or non-isolated, depending on the circuit design | Commonly 18–32 VDC | Approximately ±0.1% to ±0.3% of span | Typically 10–40 ms | PLC, DCS, SCADA, and panel-mounted instrumentation | Check DIN-rail dimensions, terminal spacing, heat dissipation, and wiring access |
| 8 | Explosion-Protected Splitter | 4–20 mA signal duplication for hazardous-area instrumentation | Typically galvanically isolated | External DC supply; intrinsically safe systems have energy limitations | Approximately ±0.1% to ±0.3% of span | Typically 10–50 ms | Oil and gas, chemical processing, and dust or gas hazardous areas | Verify the exact hazardous-area certification, zone classification, and wiring rules |
| 9 | High-Density Multi-Channel Splitter | Multiple independent 1-to-2 or 1-to-3 channels in one enclosure | Channel isolation varies; individual channel isolation is preferable | Shared external DC supply is common | Approximately ±0.1% to ±0.2% of span | Typically 10–40 ms | Large control panels and systems with limited cabinet space | Compare channel density, per-channel diagnostics, thermal load, and spare capacity |
| 10 | Universal Input Signal Splitter | Configurable input for 4–20 mA, voltage, RTD, or thermocouple signals with 4–20 mA outputs | Often isolated, subject to the selected input and output configuration | External DC supply, commonly 18–32 VDC | Approximately ±0.1% to ±0.3% of span | Typically 20–100 ms | Mixed-signal projects, replacement stock, and changing process instrumentation | Check configuration software, sensor compatibility, cold-junction compensation, and calibration method |